!   Copyright (c) Ruckus Networks, Inc. All rights reserved.
!     UNIT 1: compiled on Apr 11 2023 at 00:06:30 labeled as SPS08095j
!       (31457280 bytes) from Primary SPS08095j.bin (UFI)
!         SW: Version 08.0.95jT211 
!       Compressed Primary Boot Code size = 786944, Version:10.1.26T225 (mnz10126)
!        Compiled on Tue Nov 29 18:13:26 2022
!     UNIT 2: compiled on Apr 11 2023 at 00:06:30 labeled as SPS08095j
!       (31457280 bytes) from Primary SPS08095j.bin (UFI)
!         SW: Version 08.0.95jT211 
!       Compressed Primary Boot Code size = 786944, Version:10.1.26T225 (mnz10126)
!     UNIT 3: compiled on Apr 11 2023 at 00:06:30 labeled as SPS08095j
!       (31457280 bytes) from Primary SPS08095j.bin (UFI)
!         SW: Version 08.0.95jT211 
!       Compressed Primary Boot Code size = 786944, Version:10.1.26T225 (mnz10126)
!     UNIT 4: compiled on Apr 11 2023 at 00:06:30 labeled as SPS08095j
!       (31457280 bytes) from Primary SPS08095j.bin (UFI)
!         SW: Version 08.0.95jT211 
!       Compressed Primary Boot Code size = 786944, Version:10.1.26T225 (mnz10126)
! 
!   HW: Stackable ICX7150-48Z-HPOE
! ==========================================================================
! UNIT 1: SL 1: ICX7150-48ZP-8X10GR POE 48-port Management Module
!       Serial  #:#SERIAL#
!       Current License: 8X10GR  
!       P-ASIC  0: type B160, rev 11  Chip BCM56160_B0
! ==========================================================================
! UNIT 1: SL 2: ICX7150-8X10GF 8-port 80G Module
! ==========================================================================
! UNIT 2: SL 1: ICX7150-48ZP-8X10GR POE 48-port Management Module
!       Serial  #:#SERIAL#
!       Software Package: BASE_SOFT_PACKAGE   
!       Current License: 8X10GR  
! ==========================================================================
! UNIT 2: SL 2: ICX7150-8X10GF 8-port 80G Module
! ==========================================================================
! UNIT 3: SL 1: ICX7150-48ZP-8X10GR POE 48-port Management Module
!       Serial  #:#SERIAL#
!       Software Package: BASE_SOFT_PACKAGE   
!       Current License: 8X10GR  
! ==========================================================================
! UNIT 3: SL 2: ICX7150-8X10GF 8-port 80G Module
! ==========================================================================
! UNIT 4: SL 1: ICX7150-48ZP-8X10GR POE 48-port Management Module
!       Serial  #:#SERIAL#
!       Software Package: BASE_SOFT_PACKAGE   
! ==========================================================================
! UNIT 4: SL 2: ICX7150-8X10GF 8-port 80G Module
! ==========================================================================
!  1000 MHz ARM processor ARMv7 88 MHz bus
!     8 MB boot flash memory
!     2 GB code flash memory
!     1 GB DRAM
! 
! The system : started=cold start   
! My stack unit ID = 1, bootup role = active
! 
! The stack unit 1 chassis info: 
! 
! Power supply 1 (AC - PoE) present, status ok
!  	Model Number:	23-1000086-01
! 	Serial Number:\x20
! 	Firmware Ver: 	32.66
! Power supply 1 Fan Air Flow Direction:  Front to Back
! Power supply 2 (AC - PoE) present, status ok
!  	Model Number:	23-1000086-01
! 	Serial Number:\x20
! 	Firmware Ver: 	32.66
! Power supply 2 Fan Air Flow Direction:  Front to Back
! 
! Fan 1 ok, speed (auto): 
! Fan 2 ok, speed (auto): 
! 
! Fan controlled temperature: 
! 	Rule 1/3 (MGMT THERMAL PLANE): XX.X deg-C
! 	Rule 2/3 (PoE THERMAL SENSOR PLANE): XX.X deg-C
! 	Rule 3/3 (MISC THERMAL PLANE): XX.X deg-C
! 
! Fan speed switching temperature thresholds:
! 	Rule 1/3 (MGMT THERMAL PLANE):
! 		Speed 2:        85<----->105 deg-C (shutdown)
! 	Rule 2/3 (PoE THERMAL SENSOR PLANE):
! 		Speed 1: NM<----->130       deg-C
! 		Speed 2:       120<----->130 deg-C
! 	Rule 3/3 (MISC THERMAL PLANE):
! 		Speed 1: NM<----->100       deg-C
! 		Speed 2:        85<----->108 deg-C
! 
! Fan 1 Air Flow Direction:  Front to Back 
! Fan 2 Air Flow Direction:  Front to Back 
! Slot 1 Current Temperature: XX.X deg-C (Sensor 1), XX.X deg-C (Sensor 2), XX.X deg-C (Sensor 3), XX.X deg-C (Sensor 4)
! Slot 2 Current Temperature: NA
! 	Warning level.......: XX.X deg-C
! 	Shutdown level......: XX.X deg-C
! Boot Prom MAC : fc5c.4536.3302
! Management MAC: fc5c.4536.3302
! 
! The stack unit 2 chassis info: 
! 
! Power supply 1 (AC - PoE) present, status ok
!  	Model Number:	23-1000086-01
! 	Serial Number:\x20
! Power supply 1 Fan Air Flow Direction:  Front to Back
! Power supply 2 (AC - PoE) present, status ok
!  	Model Number:	23-1000086-01
! 	Serial Number:\x20
! 	Firmware Ver: 	32.66
! Power supply 2 Fan Air Flow Direction:  Front to Back
! 
! Fan 1 ok, speed (auto): 
! Fan 2 ok, speed (auto): 
! 
! Fan controlled temperature: 
! 	Rule 1/3 (MGMT THERMAL PLANE): XX.X deg-C
! 	Rule 2/3 (PoE THERMAL SENSOR PLANE): XX.X deg-C
! 	Rule 3/3 (MISC THERMAL PLANE): XX.X deg-C
! 
! Fan speed switching temperature thresholds:
! 	Rule 1/3 (MGMT THERMAL PLANE):
! 		Speed 1: NM<-----> 95       deg-C
! 		Speed 2:        85<----->105 deg-C (shutdown)
! 	Rule 2/3 (PoE THERMAL SENSOR PLANE):
! 		Speed 1: NM<----->130       deg-C
! 		Speed 2:       120<----->130 deg-C
! 		Speed 1: NM<----->100       deg-C
! 		Speed 2:        85<----->108 deg-C
! 
! Fan 1 Air Flow Direction:Front to Back
! Fan 2 Air Flow Direction:Front to Back
! Slot 1 Current Temperature: XX.X deg-C (Sensor 1), XX.X deg-C (Sensor 2), XX.X deg-C (Sensor 3), XX.X deg-C (Sensor 4)
! Slot 2 Current Temperature: NA
! 	Warning level.......: XX.X deg-C
! 	Shutdown level......: XX.X deg-C
! Boot Prom MAC : fc5c.4536.5e82
! 
! The stack unit 3 chassis info: 
! 
! Power supply 1 (AC - PoE) present, status ok
!  	Model Number:	23-1000086-01
! 	Serial Number:\x20
! 	Firmware Ver: 	32.66
! Power supply 1 Fan Air Flow Direction:  Front to Back
! Power supply 2 (AC - PoE) present, status ok
!  	Model Number:	23-1000086-01
! 	Serial Number:\x20
! 	Firmware Ver: 	32.66
! 
! Fan 1 ok, speed (auto): 
! Fan 2 ok, speed (auto): 
! 
! Fan controlled temperature: 
! 	Rule 1/3 (MGMT THERMAL PLANE): XX.X deg-C
! 	Rule 2/3 (PoE THERMAL SENSOR PLANE): XX.X deg-C
! 	Rule 3/3 (MISC THERMAL PLANE): XX.X deg-C
! 
! Fan speed switching temperature thresholds:
! 	Rule 1/3 (MGMT THERMAL PLANE)***active***:
! 		Speed 1: NM<-----> 95       deg-C
! 		Speed 2:        85<----->105 deg-C (shutdown)
! 	Rule 2/3 (PoE THERMAL SENSOR PLANE):
! 		Speed 1: NM<----->130       deg-C
! 		Speed 2:       120<----->130 deg-C
! 	Rule 3/3 (MISC THERMAL PLANE):
! 		Speed 1: NM<----->100       deg-C
! 		Speed 2:        85<----->108 deg-C
! 
! Fan 1 Air Flow Direction:Front to Back
! Fan 2 Air Flow Direction:Front to Back
! Slot 2 Current Temperature: NA
! 	Warning level.......: XX.X deg-C
! 	Shutdown level......: XX.X deg-C
! Boot Prom MAC : fc5c.4536.3376
! 
! The stack unit 4 chassis info: 
! 
! Power supply 1 (AC - PoE) present, status ok
!  	Model Number:	23-1000086-01
! 	Serial Number:\x20
! 	Firmware Ver: 	32.66
! Power supply 1 Fan Air Flow Direction:  Front to Back
! Power supply 2 (AC - PoE) present, status ok
!  	Model Number:	23-1000086-01
! 	Serial Number:\x20
! 	Firmware Ver: 	32.66
! Power supply 2 Fan Air Flow Direction:  Front to Back
! 
! Fan 1 ok, speed (auto): 
! Fan 2 ok, speed (auto): 
! 
! Fan controlled temperature: 
! 	Rule 2/3 (PoE THERMAL SENSOR PLANE): XX.X deg-C
! 	Rule 3/3 (MISC THERMAL PLANE): XX.X deg-C
! 
! Fan speed switching temperature thresholds:
! 	Rule 1/3 (MGMT THERMAL PLANE):
! 		Speed 1: NM<-----> 95       deg-C
! 		Speed 2:        85<----->105 deg-C (shutdown)
! 	Rule 2/3 (PoE THERMAL SENSOR PLANE):
! 		Speed 1: NM<----->130       deg-C
! 		Speed 2:       120<----->130 deg-C
! 	Rule 3/3 (MISC THERMAL PLANE):
! 		Speed 1: NM<----->100       deg-C
! 		Speed 2:        85<----->108 deg-C
! 
! Fan 1 Air Flow Direction:Front to Back
! Fan 2 Air Flow Direction:Front to Back
! Slot 1 Current Temperature: XX.X deg-C (Sensor 1), XX.X deg-C (Sensor 2), XX.X deg-C (Sensor 3), XX.X deg-C (Sensor 4)
! Slot 2 Current Temperature: NA
! 	Warning level.......: XX.X deg-C
! 	Shutdown level......: XX.X deg-C
! Boot Prom MAC : fc5c.4536.2d92
! Stack unit 1:
!   NAND Type: Micron NAND 2GiB (x 1)
!   Compressed Pri Code size = 31457280, Version:08.0.95jT211 (SPS08095j.bin)
!   Compressed Sec Code size = 33554432, Version:08.0.95hT213 (SPR08095h.bin)
!   Compressed Pri Boot Code size = 786944, Version:10.1.26T225 (mnz10126)
!   Compressed Sec Boot Code size = 786944, Version:10.1.25T225 (mnz10125)
! 
! Stack unit 2: 
!   NAND Type: Micron NAND 2GiB (x 1)
!   Compressed Pri Code size = 31457280, Version:08.0.95jT211 (SPS08095j.bin)
!   Compressed Sec Code size = 33554432, Version:08.0.95hT213 (SPR08095h.bin)
!   Compressed Pri Boot Code size = 786944, Version:10.1.26T225 (mnz10126)
!   Compressed Sec Boot Code size = 786944, Version:10.1.25T225 (mnz10125)
! 
! Stack unit 3: 
!   NAND Type: Micron NAND 2GiB (x 1)
!   Compressed Pri Code size = 31457280, Version:08.0.95jT211 (SPS08095j.bin)
!   Compressed Sec Code size = 33554432, Version:08.0.95hT213 (SPR08095h.bin)
!   Compressed Pri Boot Code size = 786944, Version:10.1.26T225 (mnz10126)
!   Compressed Sec Boot Code size = 786944, Version:10.1.25T225 (mnz10125)
! 
! Stack unit 4: 
!   NAND Type: Micron NAND 2GiB (x 1)
!   Compressed Sec Code size = 33554432, Version:08.0.95hT213 (SPR08095h.bin)
!   Compressed Pri Boot Code size = 786944, Version:10.1.26T225 (mnz10126)
!   Compressed Sec Boot Code size = 786944, Version:10.1.25T225 (mnz10125)
! 
!        Module                                         Status Ports Starting MAC  
! U1:M1  ICX7150-48ZP POE 48-port Management Module       OK     48   fc5c.4536.3302
! U1:M2  ICX7150-8X10GF 8-port 80G Module                 OK     8    fc5c.4536.3333
! U2:M1  ICX7150-48ZP POE 48-port Management Module       OK     48   fc5c.4536.5e82
! U2:M2  ICX7150-8X10GF 8-port 80G Module                 OK     8    fc5c.4536.5eb3
! U3:M1  ICX7150-48ZP POE 48-port Management Module       OK     48   fc5c.4536.3376
! U3:M2  ICX7150-8X10GF 8-port 80G Module                 OK     8    fc5c.4536.33a7
! U4:M1  ICX7150-48ZP POE 48-port Management Module       OK     48   fc5c.4536.2d92
! U4:M2  ICX7150-8X10GF 8-port 80G Module                 OK     8    fc5c.4536.2dc3
ver 08.0.95jT211
!
stack unit 1
  module 1 icx7150-48zp-poe-port-management-module
  module 2 icx7150-8-sfp-plus-port-80g-module
  priority 255
  stack-port 1/2/1
  stack-port 1/2/3
stack unit 2
  module 1 icx7150-48zp-poe-port-management-module
  module 2 icx7150-8-sfp-plus-port-80g-module
  priority 250
  stack-port 2/2/1
  stack-port 2/2/3
stack unit 3
  module 1 icx7150-48zp-poe-port-management-module
  module 2 icx7150-8-sfp-plus-port-80g-module
  priority 100
  stack-port 3/2/1
  stack-port 3/2/3
stack unit 4
  module 2 icx7150-8-sfp-plus-port-80g-module
  priority 240
  stack-port 4/2/1
  stack-port 4/2/3
stack enable
stack mac fc5c.4536.3302
!
!
no global-stp
!
lag uplink-aggregate dynamic id 100
 ports ethe 1/2/5 to 1/2/6 ethe 2/2/5 to 2/2/6 ethe 3/2/5 to 3/2/6 ethe 4/2/5 to 4/2/6 
!
!
!
vlan 1 name DEFAULT-VLAN by port
 no spanning-tree
!
vlan 70 name Printers by port
 tagged lag 100 
 no spanning-tree
!
 tagged lag 100 
 untagged ethe 1/1/1 to 1/1/16 ethe 2/1/1 to 2/1/16 
 no spanning-tree
!
!
!
!
!
!
!
!
!
!
!
!
!
aaa authentication web-server default local
aaa authentication login default tacacs+ enable local
aaa authentication login privilege-mode
aaa authorization exec default tacacs+
aaa accounting exec default start-stop tacacs+
aaa accounting system default start-stop tacacs+
boot sys fl pri
enable aaa console
#HOSTNAME# hostname
ip address #IPADDRESS# #IPADDRESS#
ip default-gateway #IPADDRESS#
!
no telnet server
username super password .....
username admin password .....
!
!
tacacs-server key 2 $byFkfW9uLW8=
snmp-server community ..... ro
snmp-server community ..... ro
snmp-server location HYD
snmp-server host #IPADDRESS# version v2c .....
snmp-server host #IPADDRESS# version v2c .....
!
!
clock timezone gmt GMT+05:30
!
!
ntp
 server #IPADDRESS#
!
!
hitless-failover enable
!
!
manager registrar
!
manager port-list 987
!
interface ethernet 1/1/1
 port-name hyd-wap-19
 no spanning-tree
 no flow-control both
!
interface ethernet 1/1/2
 no spanning-tree
 no flow-control both
!
interface ethernet 1/1/3
 port-name hyd-wap-20
 no spanning-tree
 no flow-control both
!
interface ethernet 1/1/4
 port-name hyd-wap-24
 no spanning-tree
 no flow-control both
!
interface ethernet 2/1/1
 port-name hyd-wap-06
 no spanning-tree
 no flow-control both
!
interface ethernet 2/1/2
 no spanning-tree
 no flow-control both
!
interface ethernet 2/1/3
 no spanning-tree
 no flow-control both
!
interface ethernet 2/1/4
 no spanning-tree
 no flow-control both
!
!
!
!
!
!
!
!
!
!
!
!
!
!
end